Spalten für Visualisierung auswählen
Alle auswählen
Alle abwählen
Standard-Auswahl
Erlaubter Ladestrom (mA)
Standard
CP PWM (% Duty Cycle)
Standard
IEC61851 State
Standard
Leistung (W)
Standard
Strom L1 (mA)
Standard
Strom L2 (mA)
Standard
Strom L3 (mA)
Standard
Widerstand CP/PE (Ohm)
Standard
Zustand Schütz
Standard
Fehlerzustand Schütz
Standard
Phase 0 Aktiv
Standard
Phase 1 Aktiv
Standard
Phase 2 Aktiv
Standard
Phase 0 Verbunden
Standard
Phase 1 Verbunden
Standard
Phase 2 Verbunden
Standard
Zeit seit Zustandswechsel
Standard
Spannung +12V
Standard
Spannung -12V
Standard
charger_state
error_state
lock_state
dc_fault_current_state
jumper_configuration
has_lock_switch
evse_version
energy_meter_type
voltage_0
voltage_1
voltage_2
local_timeout
global_timeout
illegal_function
illegal_data_access
illegal_data_value
slave_device_failure
led_state
car_stopped_charging
uptime
adc_cp_pe_before_pwm_high
adc_cp_pe_after_pwm_high
adc_cp_pe_before_pwm_low
adc_cp_pe_after_pwm_low
adc_pp_pe
adc_plus_12v
adc_minus_12v
voltage_cp_pe_before_pwm_high
voltage_cp_pe_after_pwm_high
voltage_cp_pe_before_pwm_low
voltage_cp_pe_after_pwm_low
voltage_pp_pe
resistance_pp_pe
gpio_config_jumper_0
gpio_motor_fault
gpio_dc_error
gpio_config_jumper_1
gpio_dc_test
gpio_gp_shutdown
gpio_button
gpio_cp_pwm
gpio_motor_input_switch
gpio_contactor
gpio_gp_output
gpio_cp_disconnect
gpio_motor_active
gpio_motor_phase
gpio_contactor_check_before
gpio_contactor_check_after
gpio_gp_input
gpio_dc_x6
gpio_dc_x30
gpio_led
gpio_20
gpio_21
gpio_22
gpio_23
slot_incoming_cable
slot_outgoing_cable
slot_shutdown_input
slot_gp_input
slot_autostart_button
slot_global
slot_user
slot_charge_manager
slot_external
slot_modbus_tcp
slot_modbus_tcp_enable
slot_ocpp
slot_charge_limits
slot_require_meter
slot_automation
slot_15
slot_16
slot_17
slot_18
slot_19
Chart anzeigen
Link kopieren
Teilbarer Link:
Konfiguration vor dem Ladeprotokoll
Konfiguration nach dem Ladeprotokoll
Log vor dem Ladeprotokoll
Log nach dem Ladeprotokoll
0,520 | | **** TINKERFORGE WARP2 CHARGER V2.6.5+6751BB89 **** 0,521 | | 319K RAM SYSTEM 282652 HEAP BYTES FREE 0,532 | | READY. 0,532 | | Last reset reason was: Software reset via esp_restart. 0,865 | main | Firmware partitions: app0 (valid, running, boot), app1 (valid) 0,998 | tools | Mounted data partition. 69632 of 3538944 bytes (2.0 %) used 1,272 | migrations | Preparing migrations 2,186 | migrations | Migrating config from 2.2.0 to 2.5.0 2,192 | migrations | Skipping migration of remote_access/config: File /migration/remote_access_config not found 2,211 | migrations | Skipping migration of remote_access/management_connection: File /migration/remote_access_management_connection not found 2,222 | migrations | Migrating config from 2.5.0 to 2.6.2 3,619 | api | WARP2 Charger config version: 2.6.2 (warp) 3,626 | esp32_eth_brick | ESP32 Ethernet Brick UID: 292u 4,034 | evse_common | Continuing to use sum of imported and exported energy for charge tracker. 4,034 | evse_common | Remove tracked charges to switch to imported energy. 4,047 | tools | EVSE 2.0 firmware is 2.2.4 not the expected 2.2.8. Flashing firmware... 4,059 | | Setting bootloader mode to bootloader. 4,070 | | Waiting for bootloader... 4,418 | | Device is in bootloader, flashing... 7,329 | | Device flashed successfully. 7,330 | | Setting bootloader mode to firmware. 7,430 | | Waiting for firmware... 7,841 | | Firmware flashed successfully 7,983 | ntp | Set timezone to Europe/Berlin 8,344 | firmware_update | Firmware is signed by: Tinkerforge GmbH 8,473 | meters | Meter in slot 1 declared 2 values. 8,784 | charge_tracker | Found 2 records: first is 1, last is 2 8,855 | charge_tracker | Last charge record size is 464 (464, 0) 9,388 | tools | NFC firmware is 2.0.6 not the expected 2.1.0. Flashing firmware... 9,389 | | Setting bootloader mode to bootloader. 9,400 | | Waiting for bootloader... 9,980 | | Device is in bootloader, flashing... 11,384 | | Device flashed successfully. 11,385 | | Setting bootloader mode to firmware. 11,448 | | Waiting for firmware... 11,930 | | Firmware flashed successfully 12,586 | meters_evse_v2 | Received values callback before detecting a meter. 12,592 | meters_evse_v2 | Received values callback before detecting a meter. 12,621 | meters | Meter in slot 0 declared 41 (38) values. 12,625 | wifi | Connecting to SBCH_IOT_24GHZ 12,660 | require_meter | Energy meter stuck or unreachable! Blocking charging. 12,672 | device_name | This is warp2-292u (warp2-292u), a WARP2 Charger Smart 22kW 13,661 | require_meter | Energy meter working again. Allowing charging. 15,204 | wifi | Connected to SBCH_IOT_24GHZ, BSSID 64:70:02:5D:AF:15 15,206 | wifi | Got IP address: 192.168.178.95/24. Own MAC address: 58:BF:25:B7:69:8C 16,599 | network | Network connected (WiFi) 17,650 | mqtt | Connected to broker at mqtt://192.168.178.90:1883. 2024-12-11 08:57:48,900 | ntp | NTP synchronized at 24,544 2024-12-11 08:58:37,028 | device_name | This is warp2-292u (warp2-292u), a WARP2 Charger Pro 22kW 2024-12-11 08:58:42,161 | users | Charger state changed from 0 to 1 2024-12-11 08:59:32,188 | users | Charger state changed from 1 to 2 2024-12-11 08:59:32,315 | charge_tracker | Tracked start of charge. 2024-12-11 08:59:35,394 | users | Charger state changed from 2 to 3 2024-12-11 09:38:29,945 | users | Charger state changed from 3 to 2 2024-12-11 10:18:30,241 | users | Charger state changed from 2 to 3 2024-12-11 10:18:32,259 | users | Charger state changed from 3 to 2 2024-12-11 10:18:33,283 | users | Charger state changed from 2 to 0 2024-12-11 10:18:33,331 | charge_tracker | Tracked end of charge. 2024-12-11 10:50:07,767 | users | Charger state changed from 0 to 1 2024-12-11 10:50:36,775 | users | Charger state changed from 1 to 2 2024-12-11 10:50:36,866 | charge_tracker | Tracked start of charge. 2024-12-11 10:50:37,871 | users | Charger state changed from 2 to 3
0,520 | | **** TINKERFORGE WARP2 CHARGER V2.6.5+6751BB89 **** 0,521 | | 319K RAM SYSTEM 282652 HEAP BYTES FREE 0,532 | | READY. 0,532 | | Last reset reason was: Software reset via esp_restart. 0,865 | main | Firmware partitions: app0 (valid, running, boot), app1 (valid) 0,998 | tools | Mounted data partition. 69632 of 3538944 bytes (2.0 %) used 1,272 | migrations | Preparing migrations 2,186 | migrations | Migrating config from 2.2.0 to 2.5.0 2,192 | migrations | Skipping migration of remote_access/config: File /migration/remote_access_config not found 2,211 | migrations | Skipping migration of remote_access/management_connection: File /migration/remote_access_management_connection not found 2,222 | migrations | Migrating config from 2.5.0 to 2.6.2 3,619 | api | WARP2 Charger config version: 2.6.2 (warp) 3,626 | esp32_eth_brick | ESP32 Ethernet Brick UID: 292u 4,034 | evse_common | Continuing to use sum of imported and exported energy for charge tracker. 4,034 | evse_common | Remove tracked charges to switch to imported energy. 4,047 | tools | EVSE 2.0 firmware is 2.2.4 not the expected 2.2.8. Flashing firmware... 4,059 | | Setting bootloader mode to bootloader. 4,070 | | Waiting for bootloader... 4,418 | | Device is in bootloader, flashing... 7,329 | | Device flashed successfully. 7,330 | | Setting bootloader mode to firmware. 7,430 | | Waiting for firmware... 7,841 | | Firmware flashed successfully 7,983 | ntp | Set timezone to Europe/Berlin 8,344 | firmware_update | Firmware is signed by: Tinkerforge GmbH 8,473 | meters | Meter in slot 1 declared 2 values. 8,784 | charge_tracker | Found 2 records: first is 1, last is 2 8,855 | charge_tracker | Last charge record size is 464 (464, 0) 9,388 | tools | NFC firmware is 2.0.6 not the expected 2.1.0. Flashing firmware... 9,389 | | Setting bootloader mode to bootloader. 9,400 | | Waiting for bootloader... 9,980 | | Device is in bootloader, flashing... 11,384 | | Device flashed successfully. 11,385 | | Setting bootloader mode to firmware. 11,448 | | Waiting for firmware... 11,930 | | Firmware flashed successfully 12,586 | meters_evse_v2 | Received values callback before detecting a meter. 12,592 | meters_evse_v2 | Received values callback before detecting a meter. 12,621 | meters | Meter in slot 0 declared 41 (38) values. 12,625 | wifi | Connecting to SBCH_IOT_24GHZ 12,660 | require_meter | Energy meter stuck or unreachable! Blocking charging. 12,672 | device_name | This is warp2-292u (warp2-292u), a WARP2 Charger Smart 22kW 13,661 | require_meter | Energy meter working again. Allowing charging. 15,204 | wifi | Connected to SBCH_IOT_24GHZ, BSSID 64:70:02:5D:AF:15 15,206 | wifi | Got IP address: 192.168.178.95/24. Own MAC address: 58:BF:25:B7:69:8C 16,599 | network | Network connected (WiFi) 17,650 | mqtt | Connected to broker at mqtt://192.168.178.90:1883. 2024-12-11 08:57:48,900 | ntp | NTP synchronized at 24,544 2024-12-11 08:58:37,028 | device_name | This is warp2-292u (warp2-292u), a WARP2 Charger Pro 22kW 2024-12-11 08:58:42,161 | users | Charger state changed from 0 to 1 2024-12-11 08:59:32,188 | users | Charger state changed from 1 to 2 2024-12-11 08:59:32,315 | charge_tracker | Tracked start of charge. 2024-12-11 08:59:35,394 | users | Charger state changed from 2 to 3 2024-12-11 09:38:29,945 | users | Charger state changed from 3 to 2 2024-12-11 10:18:30,241 | users | Charger state changed from 2 to 3 2024-12-11 10:18:32,259 | users | Charger state changed from 3 to 2 2024-12-11 10:18:33,283 | users | Charger state changed from 2 to 0 2024-12-11 10:18:33,331 | charge_tracker | Tracked end of charge. 2024-12-11 10:50:07,767 | users | Charger state changed from 0 to 1 2024-12-11 10:50:36,775 | users | Charger state changed from 1 to 2 2024-12-11 10:50:36,866 | charge_tracker | Tracked start of charge. 2024-12-11 10:50:37,871 | users | Charger state changed from 2 to 3 2024-12-11 11:03:06,828 | users | Charger state changed from 3 to 2